rapids/docs/datastreams/mandatory-empatica-format.md

2.8 KiB

Mandatory Empatica Format

This is a description of the format RAPIDS needs to process data for the following Empatica sensors.

??? info "EMPATICA_ACCELEROMETER"

| RAPIDS column   | Description                                                  |
|-----------------|--------------------------------------------------------------|
| TIMESTAMP       | An UNIX timestamp (13 digits) when a row of data was logged  |
| DEVICE_ID       | A string that uniquely identifies a device                   |
| DOUBLE_VALUES_0 | x axis of acceleration                                       |
| DOUBLE_VALUES_1 | y axis of acceleration                                       |
| DOUBLE_VALUES_2 | z axis of acceleration                                       |

??? info "EMPATICA_HEARTRATE"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| HEARTRATE |  Intraday heartrate |

??? info "EMPATICA_TEMPERATURE"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| TEMPERATURE |  temperature |

??? info "EMPATICA_ELECTRODERMAL_ACTIVITY"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| ELECTRODERMAL_ACTIVITY |  electrical conductance |

??? info "EMPATICA_BLOOD_VOLUME_PULSE"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| BLOOD_VOLUME_PULSE |  blood volume pulse |

??? info "EMPATICA_INTER_BEAT_INTERVAL"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| INTER_BEAT_INTERVAL |  inter beat interval |

??? info "EMPATICA_TAGS"

| RAPIDS column   | Description   |
|-----------------|-----------------|
| TIMESTAMP       |  An UNIX timestamp (13 digits) when a row of data was logged (automatically created by RAPIDS) |
| DEVICE_ID       |  A string that uniquely identifies a device |
| TAGS |  tags |