# Empatica Electrodermal Activity
|
|||
|
|
|||
|
Sensor parameters description for `[EMPATICA_ELECTRODERMAL_ACTIVITY]`:
|
|||
|
|
|||
|
|Key | Description |
|
|||
|
|----------------|-----------------------------------------------------------------------------------------------------------------------------------
|
|||
|
|`[TABLE]`| Name of the CSV file containing electrodermal activity data that is compressed inside an Empatica zip file. Since these zip files are created [automatically](https://support.empatica.com/hc/en-us/articles/201608896-Data-export-and-formatting-from-E4-connect-) by Empatica, there is no need to change the value of this attribute.
|
|||
|
|
|||
|
## DBDP provider
|
|||
|
|
|||
|
!!! info "Available time segments and platforms"
|
|||
|
- Available for all time segments
|
|||
|
|
|||
|
!!! info "File Sequence"
|
|||
|
```bash
|
|||
|
- data/raw/{pid}/empatica_electrodermal_activity_unzipped_{zip-file}.csv # one per zip file
|
|||
|
- data/raw/{pid}/empatica_electrodermal_activity_raw_{zip-file}.csv # one per zip file
|
|||
|
- data/raw/{pid}/empatica_electrodermal_activity_joined.csv
|
|||
|
- data/raw/{pid}/empatica_electrodermal_activity_with_datetime.csv
|
|||
|
- data/interim/{pid}/empatica_electrodermal_activity_features/empatica_electrodermal activity_{language}_{provider_key}.csv
|
|||
|
- data/processed/features/{pid}/empatica_electrodermal_activity.csv
|
|||
|
```
|
|||
|
|
|||
|
|
|||
|
Parameters description for `[EMPATICA_ELECTRODERMAL_ACTIVITY][PROVIDERS][DBDP]`:
|
|||
|
|
|||
|
|Key | Description |
|
|||
|
|----------------|-----------------------------------------------------------------------------------------------------------------------------------
|
|||
|
|`[COMPUTE]` | Set to `True` to extract `EMPATICA_ELECTRODERMAL_ACTIVITY` features from the `DBDP` provider|
|
|||
|
|`[FEATURES]` | Features to be computed from electrodermal activity intraday data, see table below |
|
|||
|
|
|||
|
|
|||
|
Features description for `[EMPATICA_ELECTRODERMAL ACTIVITY][PROVIDERS][DBDP]`:
|
|||
|
|
|||
|
|Feature |Units |Description|
|
|||
|
|-------------------------- |-------------- |---------------------------|
|
|||
|
|maxeda |microsiemens |The maximum electrical conductance during a time segment.
|
|||
|
|mineda |microsiemens |The minimum electrical conductance during a time segment.
|
|||
|
|avgeda |microsiemens |The average electrical conductance during a time segment.
|
|||
|
|medianeda |microsiemens |The median of electrical conductance during a time segment.
|
|||
|
|modeeda |microsiemens |The mode of electrical conductance during a time segment.
|
|||
|
|stdeda |microsiemens |The standard deviation of electrical conductance during a time segment.
|
|||
|
|diffmaxmodeeda |microsiemens |The difference between the maximum and mode electrical conductance during a time segment.
|
|||
|
|diffminmodeeda |microsiemens |The difference between the mode and minimum electrical conductance during a time segment.
|
|||
|
|entropyeda |nats |Shannon’s entropy measurement based on electrical conductance during a time segment.
|
|||
|
|
|||
|
!!! note "Assumptions/Observations"
|
|||
|