48 lines
3.3 KiB
Markdown
48 lines
3.3 KiB
Markdown
|
# Empatica Blood Volume Pulse
|
|||
|
|
|||
|
Sensor parameters description for `[EMPATICA_BLOOD_VOLUME_PULSE]`:
|
|||
|
|
|||
|
|Key | Description |
|
|||
|
|----------------|-----------------------------------------------------------------------------------------------------------------------------------
|
|||
|
|`[TABLE]`| Name of the CSV file containing blood volume pulse data that is compressed inside an Empatica zip file. Since these zip files are created [automatically](https://support.empatica.com/hc/en-us/articles/201608896-Data-export-and-formatting-from-E4-connect-) by Empatica, there is no need to change the value of this attribute.
|
|||
|
|
|||
|
## DBDP provider
|
|||
|
|
|||
|
!!! info "Available time segments and platforms"
|
|||
|
- Available for all time segments
|
|||
|
|
|||
|
!!! info "File Sequence"
|
|||
|
```bash
|
|||
|
- data/raw/{pid}/empatica_blood_volume_pulse_unzipped_{zip-file}.csv # one per zip file
|
|||
|
- data/raw/{pid}/empatica_blood_volume_pulse_raw_{zip-file}.csv # one per zip file
|
|||
|
- data/raw/{pid}/empatica_blood_volume_pulse_joined.csv
|
|||
|
- data/raw/{pid}/empatica_blood_volume_pulse_with_datetime.csv
|
|||
|
- data/interim/{pid}/empatica_blood_volume_pulse_features/empatica_blood_volume_pulse_{language}_{provider_key}.csv
|
|||
|
- data/processed/features/{pid}/empatica_blood_volume_pulse.csv
|
|||
|
```
|
|||
|
|
|||
|
|
|||
|
Parameters description for `[EMPATICA_BLOOD_VOLUME_PULSE][PROVIDERS][DBDP]`:
|
|||
|
|
|||
|
|Key | Description |
|
|||
|
|----------------|-----------------------------------------------------------------------------------------------------------------------------------
|
|||
|
|`[COMPUTE]` | Set to `True` to extract `EMPATICA_BLOOD_VOLUME_PULSE` features from the `DBDP` provider|
|
|||
|
|`[FEATURES]` | Features to be computed from blood volume pulse intraday data, see table below |
|
|||
|
|
|||
|
|
|||
|
Features description for `[EMPATICA_BLOOD_VOLUME_PULSE][PROVIDERS][DBDP]`:
|
|||
|
|
|||
|
|Feature |Units |Description|
|
|||
|
|-------------------------- |-------------- |---------------------------|
|
|||
|
|maxbvp |- |The maximum blood volume pulse during a time segment.
|
|||
|
|minbvp |- |The minimum blood volume pulse during a time segment.
|
|||
|
|avgbvp |- |The average blood volume pulse during a time segment.
|
|||
|
|medianbvp |- |The median of blood volume pulse during a time segment.
|
|||
|
|modebvp |- |The mode of blood volume pulse during a time segment.
|
|||
|
|stdbvp |- |The standard deviation of blood volume pulse during a time segment.
|
|||
|
|diffmaxmodebvp |- |The difference between the maximum and mode blood volume pulse during a time segment.
|
|||
|
|diffminmodebvp |- |The difference between the mode and minimum blood volume pulse during a time segment.
|
|||
|
|entropybvp |nats |Shannon’s entropy measurement based on blood volume pulse during a time segment.
|
|||
|
|
|||
|
!!! note "Assumptions/Observations"
|
|||
|
For more information about BVP read [this](https://support.empatica.com/hc/en-us/articles/360029719792-E4-data-BVP-expected-signal).
|